DIGITAL LIBRARY



JUDUL:ANALISIS KESELAMATAN DAN KESEHATAN KERJA DI NURSERY PT JORONG BARUTAMA GRESTON
PENGARANG:NOOR HAYATUNNISA
PENERBIT:UNIVERSITAS LAMBUNG MANGKURAT
TANGGAL:2026-08-04


ABSTRAK

 

NOOR HAYATUNNISA. 2026. “Analisis Sistem Pengkondisian Udara Dan Pencahayaan Untuk Efisiensi Energi Di PT Jorong Barutama Greston”. Skripsi, Program Studi Kehutanan Fakultas Kehutanan Universitas Lambung Mangkurat. Pembimbing : Dr. Adi Rahmadi, S.Hut., M.T. dan Ir. Noor Mirad Sari, M.P.

 

Kata Kunci: Efisiensi energi, intensitas konsumsi energi, pencahayaan, pengkondisian udara, audit energi

 

Penelitianinibertujuanuntukmenganalisissistempengkondisianudaradan pencahayaan guna mendukung efisiensi energi di kantor PT Jorong Barutama Greston (PT JBG), perusahaan tambang batubara yang berlokasi di Kabupaten Tanah Laut, Kalimantan Selatan. Metode yang digunakan meliputi audit energi awal dengan pengumpulan data konsumsi listrik selama periode April–September 2025, pengukuran intensitas pencahayaan, analisis Intensitas Konsumsi Energi (IKE), penerapan metode Simple Moving Average 6 Bulan (SMA-6), serta wawancara dan kuesioner kepada departemen HRD dan SDM untuk mengkaji tingkat pemahaman dan kesadaran karyawan terhadap efisiensi energi. Hasil penelitian menunjukkan bahwa total konsumsi energi gedung selama enam bulan mencapai 281.996 kWh dengan rata-rata IKE sebesar 130,54 kWh/m²/tahun yang masukkategoricukupefisien,namunkondisiiniterancammemburukkarenapada bulan September IKEmelonjaktajam hingga 155,07 kWh/m² atau masuk kategori boros. Dua komponen penyumbang konsumsi energi terbesar adalah sistem pencahayaan, dengan 23 unit lampu LED beroperasi penuh 24 jam tanpa penjadwalandansebagianbesarruanganbelummemenuhistandarSNI6197:2020, serta sistem VAC dengan 12 unit AC yang mencatat IKE sebesar 15,43 kWh/m² per bulan, melampaui standar efisiensi sebesar ≤10 kWh/m². Dari aspek sumber daya manusia, pemahaman karyawan sudah cukup baik pada tataran kebijakan, namun penerapan budaya hemat energi dalam keseharian masih belum optimal akibat tidak adanya sensor otomatis, minimnya insentif hemat energi, serta keterbatasan keterlibatan karyawan dalam pengambilan keputusan terkait kondisi lingkungan kerja. Apabila seluruh rekomendasi efisiensi diterapkan secara konsisten,PTJBGberpotensimenghematsekitar20–25%daritotalkonsumsiatau setara dengan 56.000–70.000 kWh per tahun tanpa memerlukan investasi penggantian peralatan secara besar-besaran.

ABSTRACT

 

 

NOOR HAYATUNNISA. 2026. "Analysis of Air Conditioning and Lighting Systems for Energy Efficiency at PT Jorong Barutama Greston". Thesis, Forestry StudyProgram,FacultyofForestry,LambungMangkuratUniversity.Advisors:Dr. Adi Rahmadi, S.Hut., M.T. and Ir. Noor Mirad Sari, M.P.

 

Keywords: Energy efficiency, energy consumption intensity, lighting, air conditioning, energy audit

 

This study aims to analyze the air conditioning and lighting systems to support energy efficiency at the office of PT Jorong Barutama Greston (PT JBG), a coal mining company located in Tanah Laut Regency, South Kalimantan. The methods employed include an initial energy audit through the collection of electricity consumption data over the period of April–September 2025, lighting intensitymeasurements,EnergyConsumptionIntensity(ECI)analysis,application of the 6-Month Simple Moving Average (SMA-6) method, as well as interviews and questionnaires administered to the HRD and HR departments to assess employees'levelofunderstandingandawarenessregardingenergyefficiency.The results indicate that the total energy consumption of the building over six months reached 281,996 kWh with an average ECI of 130.54 kWh/m²/year, classified as moderately efficient; however, this condition is at risk of deteriorating as the ECI spiked sharply to 155.07 kWh/m²in September, fallinginto the wasteful category. Thetwolargestcontributorstoenergyconsumptionarethelightingsystem —with 23 LED units operating continuously for 24 hours without scheduling and most rooms failing to meet SNI 6197:2020 standards — and the VAC system, with 12 airconditioningunitsrecordinganECIof15.43kWh/m²permonth,exceedingthe efficiency standard of ≤10 kWh/m². From a human resource perspective, employees'understandingatthepolicylevelisreasonablygood;however,thedaily practice of energy-saving culture remains suboptimal due to the absence of automatic sensors, limited energy-saving incentives, and insufficient employee involvementin decision-making related toworkplaceenvironmentalconditions. If all efficiency recommendations are consistently implemented, PT JBG has the potential to save approximately 20–25% of total consumption, equivalent to 56,000–70,000kWhperyear,withoutrequiringlarge-scaleequipmentreplacement investments.

Berkas PDF
NODOWNLOAD LINK
1FILE 1



File secara keseluruhan dapat di unduh DISINI